ISO/FDIS 11197:2026 Medical Supply Units: Buyer’s Compliance Guide

The ISO/FDIS 11197:2026 medical supply units final draft, now at the FDIS ballot stage, is not just a routine standards update. For overseas hospital procurement teams, EPC contractors, and clinical planners sourcing casework and headwalls, this revision changes who is legally responsible for compliance and what documentation you must demand from your supplier. The standard now explicitly treats any party assembling components on-site as the manufacturer, aligning with EU MDR 2017/745 obligations. This article translates the technical changes into concrete sourcing actions: what to verify in your supplier’s documentation, how to structure your RFQ, and how to protect your project timeline and legal position.

What ISO/FDIS 11197:2026 Changes for Your Project

The 2026 edition, currently at stage 50.20 (FDIS ballot initiated July 23, 2026), updates the 2019 version. The Bulgarian Institute for Standardization confirms the FDIS stage and its relation to EU MDR 2017/745. The most consequential change is the explicit manufacturer definition: if your contractor assembles a medical supply unit on-site from components, that contractor is now legally the manufacturer under the standard. This has direct implications for liability, technical documentation, and post-market surveillance obligations.

For buyers, this means your contract must clearly assign manufacturer responsibilities. If your supplier ships a complete unit, they are the manufacturer. If you or your local contractor assembles components, you inherit those obligations. This is not a subtle legal nuance; it affects who must hold technical files, who conducts the risk assessment, and who responds to a regulatory inquiry.

ISO/FDIS 11197:2026 medical supply units headwall in a hospital patient room
ISO/FDIS 11197:2026 medical supply units headwall in a hospital patient room | ZHOBAI Medical Furniture

Key Changes from ISO 11197:2019: What to Verify

While the full text is not yet public, the FDIS scope and structure indicate several areas of change that buyers should pre-emptively address in their specifications:

  • Manufacturer definition: As noted, on-site assembly now implies manufacturer status. Insist on a clear statement in your contract about who holds that role.
  • Alignment with EU MDR: The FDIS explicitly references EU MDR 2017/745. If your project is in the EU/EEA, your supplier’s technical documentation must align with MDR requirements, including clinical evaluation and post-market surveillance. Verify they have a documented process for this.
  • Testing and verification: Expect more rigorous testing requirements for mechanical strength, electrical safety (if applicable), and cleanability. Request the supplier’s test reports for the specific model you are buying, not just a generic certificate.
  • Documentation: The standard likely requires a more comprehensive technical file. Ask for a document list before you place an order.

For a detailed comparison of the 2019 and 2026 editions, refer to our guide on medical furniture material compliance testing.

On-Site Assembly: Who Is the Manufacturer?

This is the single most important change for overseas buyers. If you are sourcing a headwall system that arrives as modules and is assembled by a local contractor, that contractor is now the manufacturer under ISO/FDIS 11197:2026. This means they must hold the technical documentation, ensure the assembled unit meets the standard, and take responsibility for any non-conformity.

In practice, this creates a risk: your local contractor may not have the engineering expertise or documentation systems to fulfil this role. The solution is to either:

  • Source fully assembled units from a single supplier who takes manufacturer responsibility, or
  • Contractually transfer manufacturer obligations to the supplier, even if assembly is on-site, and have them provide supervision and sign-off.

We have seen projects where this ambiguity led to delays during commissioning. Address it in your RFQ by asking: “Who is the manufacturer of the medical supply unit? Please provide your technical file index and declare your compliance pathway.”

Alignment with EU MDR 2017/745: Documentation You Must Request

The FDIS is aligned with EU MDR, which has been fully applicable since May 2021. For medical supply units that are medical devices (e.g., those that incorporate medical gas outlets or electrical patient monitoring), the MDR requires:

  • Technical documentation demonstrating conformity
  • A Declaration of Conformity (DoC)
  • CE marking, if the product is classified as a medical device
  • Registration with the competent authority

However, not all medical supply units are medical devices. A simple headwall with no medical gas or electrical patient connections may fall outside the MDR. Your supplier should provide a classification assessment. Ask for a written statement from your supplier stating whether the product is a medical device under EU MDR, and if so, provide the DoC and CE certificate. If not, request a rationale.

Engineer inspecting a medical supply unit with a checklist in a factory
Engineer inspecting a medical supply unit with a checklist in a factory | ZHOBAI Medical Furniture

Sourcing Considerations for Overseas Buyers

When sourcing from China, the revision affects your supplier evaluation in several ways:

  • Documentation: Verify that the supplier has a technical file that meets ISO 11197:2026. Ask for the document index and sample pages.
  • Testing: Request test reports from an accredited laboratory. Be wary of suppliers who only provide a “certificate of compliance” without underlying data.
  • Quality system: The supplier should have ISO 13485 or ISO 9001 certification. ISO 13485 is the medical device quality management standard and is more relevant for MDR compliance.
  • Experience: Ask for references of projects that have undergone regulatory review in your target market.

We have compiled a checklist of documentation to request in our blog on hospital furniture factory audit standards.

Supply Chain Context: GB/T 46489-2025 and Chinese Manufacturing

The Chinese domestic standard GB/T 46489-2025 for hospital furniture, effective May 1, 2026, signals an improving quality baseline in the Chinese supply chain. This standard covers general requirements for hospital furniture, including materials, construction, and safety. While it is not equivalent to ISO 11197, it indicates that Chinese manufacturers are increasingly familiar with structured quality standards. For export buyers, this means the gap between domestic and international compliance is narrowing, but you still need to verify ISO 11197 compliance specifically.

How to Structure Your RFQ and Supplier Evaluation

Use the following table to compare supplier responses regarding ISO/FDIS 11197:2026 compliance:

Evaluation Criterion What to Ask Acceptable Evidence
Manufacturer status Who is the manufacturer of the medical supply unit? Contractual statement, technical file index
Technical documentation Can you provide the technical file index and sample pages? Document index, risk assessment, clinical evaluation (if applicable)
Testing What tests have been performed on this model? Test reports from accredited lab (e.g., IEC 60601-1, ISO 11197 specific tests)
Quality system Do you hold ISO 13485 or ISO 9001? Valid certificate
EU MDR alignment Is this product a medical device under EU MDR? If yes, provide DoC and CE certificate. DoC, CE certificate, classification rationale
On-site assembly If assembly is on-site, who assumes manufacturer responsibility? Contract clause, supervision plan

Incorporate these questions into your RFQ. At ZHOBAI Medical Furniture, we provide a complete technical file index and third-party test reports for our medical supply units, and we clearly define manufacturer responsibility in our contracts.

Hospital procurement team reviewing technical documents for medical supply units
Hospital procurement team reviewing technical documents for medical supply units | ZHOBAI Medical Furniture

Decision Framework: Build vs. Buy vs. Local Assembly

Your sourcing decision should weigh the following:

  • Fully assembled from one supplier: Simplest for compliance, but shipping costs and lead times are higher.
  • Modular with supplier-supervised assembly: Reduces shipping volume, but requires clear manufacturer transfer and supervision.
  • Local assembly by contractor: Lowest cost, but the contractor must meet ISO 11197:2026 as manufacturer, which may be beyond their capability.

For most overseas projects, the second option offers a balance. Ensure your supplier provides installation drawings, torque specifications, and a sign-off checklist to transfer responsibility safely.

Frequently Asked Questions

Does ISO/FDIS 11197:2026 apply to all medical furniture?

No. It applies to medical supply units, which are cabinetry or enclosures that incorporate patient care services such as medical gas outlets, electrical sockets, or monitoring equipment. General hospital furniture like beds or chairs is not covered.

Is CE marking required for medical supply units?

Only if the product is classified as a medical device under EU MDR. A simple headwall without medical gas or electrical patient connections may not require CE marking. Your supplier must provide a classification assessment.

What happens if my supplier is not aware of the 2026 revision?

That is a red flag. A competent supplier should be tracking standard revisions. If they are not, they may not be able to provide the required documentation.

Can I use the 2019 edition for a project in 2026?

It depends on the regulatory requirements of your destination country. Some jurisdictions may accept the 2019 edition during a transition period, but the FDIS indicates the 2026 edition will become the reference. Check with your local authority or notified body.

How do I verify a supplier’s test reports?

Request the test report number and the laboratory’s accreditation certificate. You can verify the accreditation on the lab’s website or through the national accreditation body.

RFQ Checklist for ISO/FDIS 11197:2026 Compliance

  • Request a statement of manufacturer identity and responsibility.
  • Ask for the technical file index and sample pages.
  • Require test reports from an accredited laboratory for the specific model.
  • Request ISO 13485 or ISO 9001 certificate.
  • If EU destination, ask for MDR classification and DoC if applicable.
  • Clarify on-site assembly responsibilities in the contract.
  • Include a clause allowing you to audit the supplier’s quality system.
  • Request references of projects with regulatory review in your market.

At ZHOBAI, we have managed projects from planning to installation, including regulatory documentation. Our team can provide the technical file index and test reports you need. Review our project portfolio to see how we have handled compliance for hospitals across multiple continents.

Practical Steps for Overseas Buyers to Manage ISO/FDIS 11197:2026 Compliance

Beyond understanding the standard’s technical changes, overseas buyers must take concrete actions to protect their projects. This section outlines practical steps for RFQ preparation, document verification, approval milestones, inspection planning, packaging review, and handover responsibilities.

RFQ Questions to Ask Your Supplier

When issuing an RFQ for medical supply units, include specific questions that address the new manufacturer definition and documentation requirements. These questions will help you evaluate supplier capability and avoid surprises later.

  • Who is the legal manufacturer of the medical supply unit? Please provide a signed statement.
  • Can you provide the technical file index and sample pages? We need to verify that the documentation meets ISO/FDIS 11197:2026 requirements.
  • What tests have been performed on this specific model? Please provide test reports from an accredited laboratory.
  • Do you hold ISO 13485 or ISO 9001 certification? Please provide a valid certificate.
  • Is this product a medical device under EU MDR 2017/745? If yes, provide the Declaration of Conformity and CE certificate. If not, provide a written rationale.
  • If on-site assembly is required, who assumes manufacturer responsibility? Please outline your supervision and sign-off process.
  • What is your process for handling post-market surveillance and vigilance reporting, if applicable?
  • Can you provide references of projects that have undergone regulatory review in our target market?

Document Checks Before Order Placement

Before placing an order, verify that the supplier’s documentation is complete and aligns with ISO/FDIS 11197:2026. Request the following documents and review them carefully:

  • Technical File Index: Ensure it includes sections on risk management, design inputs/outputs, verification and validation, and labeling.
  • Test Reports: Check that tests are performed on the exact model you are buying, not a similar one. Verify the laboratory’s accreditation.
  • Quality System Certificate: Confirm ISO 13485 or ISO 9001 is current and covers the manufacturing site.
  • EU MDR Classification: If the product is a medical device, request the classification rationale and DoC. If not, get a written statement.
  • Manufacturer Declaration: A signed document stating who is the manufacturer and their responsibilities.

Approval Milestones in Your Project Plan

Incorporate approval milestones into your project timeline to ensure compliance is verified at key stages. This prevents last-minute surprises and allows time for corrective actions.

  1. Design Approval: Review and approve the design drawings and technical specifications before production begins.
  2. Pre-Production Sample: Request a sample unit for your team to inspect and test against your requirements.
  3. Production Inspection: Conduct a mid-production inspection to verify that materials and workmanship meet the approved design.
  4. Final Inspection: Perform a final inspection before shipment, including functional tests and documentation review.
  5. Documentation Approval: Approve the final technical file and certificates before shipment.

Inspection Planning

Plan inspections to verify compliance with ISO/FDIS 11197:2026. Consider hiring a third-party inspection agency if you cannot visit the factory yourself.

  • Pre-Shipment Inspection: Check that the units are manufactured according to the approved design and that all components are correctly installed.
  • Documentation Audit: Verify that the technical file is complete and matches the shipped units.
  • Testing Witness: If possible, witness key tests such as electrical safety and mechanical strength at the supplier’s facility or an accredited lab.

Packaging Review

Proper packaging is essential to prevent damage during transit and to ensure that installation instructions and documentation are included. Review the packaging plan with your supplier.

  • Protective Packaging: Ensure that units are protected against moisture, shock, and vibration during shipping.
  • Labeling: Check that each package is labeled with the product name, model number, quantity, and handling instructions.
  • Documentation Enclosed: Confirm that installation manuals, technical files, and certificates are included in the shipment.

Handover Responsibilities

Clearly define handover responsibilities to avoid disputes and ensure a smooth installation. This is especially important if on-site assembly is involved.

  • Supplier Responsibilities: Provide installation drawings, torque specifications, and a sign-off checklist. If the supplier supervises assembly, they must ensure the final unit meets the standard.
  • Buyer Responsibilities: Ensure that the installation site is ready, and that local contractors follow the supplier’s instructions.
  • Transfer of Manufacturer Role: If the buyer or local contractor assembles the unit, they must formally accept manufacturer responsibilities. This should be documented in the contract.

Post-Installation Support

After installation, maintain a clear channel for post-market surveillance and support. The manufacturer (or the party assuming that role) must have a process for handling complaints and reporting serious incidents to regulators.

  • Complaint Handling: Ensure the supplier has a documented process for receiving and investigating complaints.
  • Vigilance Reporting: If the product is a medical device, the manufacturer must report serious incidents to the competent authority. Verify that this process is in place.
  • Spare Parts and Maintenance: Confirm the availability of spare parts and maintenance services for the expected lifespan of the unit.

Final Checklist for Overseas Buyers

Use this checklist to ensure you have covered all aspects of ISO/FDIS 11197:2026 compliance in your sourcing process:

  • RFQ includes questions on manufacturer status, documentation, testing, and EU MDR alignment.
  • Technical file index and sample pages reviewed.
  • Test reports verified from an accredited laboratory.
  • Quality system certificate (ISO 13485 or ISO 9001) checked.
  • EU MDR classification and DoC (if applicable) obtained.
  • On-site assembly responsibilities clearly defined in the contract.
  • Approval milestones set and documented.
  • Inspection plan agreed upon.
  • Packaging plan reviewed.
  • Handover responsibilities and post-installation support confirmed.

By following these practical steps, you can mitigate risks and ensure that your medical supply units meet the requirements of ISO/FDIS 11197:2026 and applicable regulations.

Practical Steps for Overseas Buyers to Manage ISO/FDIS 11197:2026 Compliance

Beyond understanding the standard’s technical changes, overseas buyers must take concrete actions to protect their projects. This section outlines practical steps for RFQ preparation, document verification, approval milestones, inspection planning, packaging review, and handover responsibilities.

RFQ Questions to Ask Your Supplier

When issuing an RFQ for medical supply units, include specific questions that address the new manufacturer definition and documentation requirements. These questions will help you evaluate supplier capability and avoid surprises later.

  • Who is the legal manufacturer of the medical supply unit? Please provide a signed statement.
  • Can you provide the technical file index and sample pages? We need to verify that the documentation meets ISO/FDIS 11197:2026 requirements.
  • What tests have been performed on this specific model? Please provide test reports from an accredited laboratory.
  • Do you hold ISO 13485 or ISO 9001 certification? Please provide a valid certificate.
  • Is this product a medical device under EU MDR 2017/745? If yes, provide the Declaration of Conformity and CE certificate. If not, provide a written rationale.
  • If on-site assembly is required, who assumes manufacturer responsibility? Please outline your supervision and sign-off process.
  • What is your process for handling post-market surveillance and vigilance reporting, if applicable?
  • Can you provide references of projects that have undergone regulatory review in our target market?

Document Checks Before Order Placement

Before placing an order, verify that the supplier’s documentation is complete and aligns with ISO/FDIS 11197:2026. Request the following documents and review them carefully:

  • Technical File Index: Ensure it includes sections on risk management, design inputs/outputs, verification and validation, and labeling.
  • Test Reports: Check that tests are performed on the exact model you are buying, not a similar one. Verify the laboratory’s accreditation.
  • Quality System Certificate: Confirm ISO 13485 or ISO 9001 is current and covers the manufacturing site.
  • EU MDR Classification: If the product is a medical device, request the classification rationale and DoC. If not, get a written statement.
  • Manufacturer Declaration: A signed document stating who is the manufacturer and their responsibilities.

Approval Milestones in Your Project Plan

Incorporate approval milestones into your project timeline to ensure compliance is verified at key stages. This prevents last-minute surprises and allows time for corrective actions.

  1. Design Approval: Review and approve the design drawings and technical specifications before production begins.
  2. Pre-Production Sample: Request a sample unit for your team to inspect and test against your requirements.
  3. Production Inspection: Conduct a mid-production inspection to verify that materials and workmanship meet the approved design.
  4. Final Inspection: Perform a final inspection before shipment, including functional tests and documentation review.
  5. Documentation Approval: Approve the final technical file and certificates before shipment.

Inspection Planning

Plan inspections to verify compliance with ISO/FDIS 11197:2026. Consider hiring a third-party inspection agency if you cannot visit the factory yourself.

  • Pre-Shipment Inspection: Check that the units are manufactured according to the approved design and that all components are correctly installed.
  • Documentation Audit: Verify that the technical file is complete and matches the shipped units.
  • Testing Witness: If possible, witness key tests such as electrical safety and mechanical strength at the supplier’s facility or an accredited lab.

Packaging Review

Proper packaging is essential to prevent damage during transit and to ensure that installation instructions and documentation are included. Review the packaging plan with your supplier.

  • Protective Packaging: Ensure that units are protected against moisture, shock, and vibration during shipping.
  • Labeling: Check that each package is labeled with the product name, model number, quantity, and handling instructions.
  • Documentation Enclosed: Confirm that installation manuals, technical files, and certificates are included in the shipment.

Handover Responsibilities

Clearly define handover responsibilities to avoid disputes and ensure a smooth installation. This is especially important if on-site assembly is involved.

  • Supplier Responsibilities: Provide installation drawings, torque specifications, and a sign-off checklist. If the supplier supervises assembly, they must ensure the final unit meets the standard.
  • Buyer Responsibilities: Ensure that the installation site is ready, and that local contractors follow the supplier’s instructions.
  • Transfer of Manufacturer Role: If the buyer or local contractor assembles the unit, they must formally accept manufacturer responsibilities. This should be documented in the contract.

Post-Installation Support

After installation, maintain a clear channel for post-market surveillance and support. The manufacturer (or the party assuming that role) must have a process for handling complaints and reporting serious incidents to regulators.

  • Complaint Handling: Ensure the supplier has a documented process for receiving and investigating complaints.
  • Vigilance Reporting: If the product is a medical device, the manufacturer must report serious incidents to the competent authority. Verify that this process is in place.
  • Spare Parts and Maintenance: Confirm the availability of spare parts and maintenance services for the expected lifespan of the unit.

Final Checklist for Overseas Buyers

Use this checklist to ensure you have covered all aspects of ISO/FDIS 11197:2026 compliance in your sourcing process:

  • RFQ includes questions on manufacturer status, documentation, testing, and EU MDR alignment.
  • Technical file index and sample pages reviewed.
  • Test reports verified from an accredited laboratory.
  • Quality system certificate (ISO 13485 or ISO 9001) checked.
  • EU MDR classification and DoC (if applicable) obtained.
  • On-site assembly responsibilities clearly defined in the contract.
  • Approval milestones set and documented.
  • Inspection plan agreed upon.
  • Packaging plan reviewed.
  • Handover responsibilities and post-installation support confirmed.

By following these practical steps, you can mitigate risks and ensure that your medical supply units meet the requirements of ISO/FDIS 11197:2026 and applicable regulations.

Practical Steps for Overseas Buyers to Manage ISO/FDIS 11197:2026 Compliance

Beyond understanding the standard’s technical changes, overseas buyers must take concrete actions to protect their projects. This section outlines practical steps for RFQ preparation, document verification, approval milestones, inspection planning, packaging review, and handover responsibilities.

RFQ Questions to Ask Your Supplier

When issuing an RFQ for medical supply units, include specific questions that address the new manufacturer definition and documentation requirements. These questions will help you evaluate supplier capability and avoid surprises later.

  • Who is the legal manufacturer of the medical supply unit? Please provide a signed statement.
  • Can you provide the technical file index and sample pages? We need to verify that the documentation meets ISO/FDIS 11197:2026 requirements.
  • What tests have been performed on this specific model? Please provide test reports from an accredited laboratory.
  • Do you hold ISO 13485 or ISO 9001 certification? Please provide a valid certificate.
  • Is this product a medical device under EU MDR 2017/745? If yes, provide the Declaration of Conformity and CE certificate. If not, provide a written rationale.
  • If on-site assembly is required, who assumes manufacturer responsibility? Please outline your supervision and sign-off process.
  • What is your process for handling post-market surveillance and vigilance reporting, if applicable?
  • Can you provide references of projects that have undergone regulatory review in our target market?

Document Checks Before Order Placement

Before placing an order, verify that the supplier’s documentation is complete and aligns with ISO/FDIS 11197:2026. Request the following documents and review them carefully:

  • Technical File Index: Ensure it includes sections on risk management, design inputs/outputs, verification and validation, and labeling.
  • Test Reports: Check that tests are performed on the exact model you are buying, not a similar one. Verify the laboratory’s accreditation.
  • Quality System Certificate: Confirm ISO 13485 or ISO 9001 is current and covers the manufacturing site.
  • EU MDR Classification: If the product is a medical device, request the classification rationale and DoC. If not, get a written statement.
  • Manufacturer Declaration: A signed document stating who is the manufacturer and their responsibilities.

Approval Milestones in Your Project Plan

Incorporate approval milestones into your project timeline to ensure compliance is verified at key stages. This prevents last-minute surprises and allows time for corrective actions.

  1. Design Approval: Review and approve the design drawings and technical specifications before production begins.
  2. Pre-Production Sample: Request a sample unit for your team to inspect and test against your requirements.
  3. Production Inspection: Conduct a mid-production inspection to verify that materials and workmanship meet the approved design.
  4. Final Inspection: Perform a final inspection before shipment, including functional tests and documentation review.
  5. Documentation Approval: Approve the final technical file and certificates before shipment.

Inspection Planning

Plan inspections to verify compliance with ISO/FDIS 11197:2026. Consider hiring a third-party inspection agency if you cannot visit the factory yourself.

  • Pre-Shipment Inspection: Check that the units are manufactured according to the approved design and that all components are correctly installed.
  • Documentation Audit: Verify that the technical file is complete and matches the shipped units.
  • Testing Witness: If possible, witness key tests such as electrical safety and mechanical strength at the supplier’s facility or an accredited lab.

Packaging Review

Proper packaging is essential to prevent damage during transit and to ensure that installation instructions and documentation are included. Review the packaging plan with your supplier.

  • Protective Packaging: Ensure that units are protected against moisture, shock, and vibration during shipping.
  • Labeling: Check that each package is labeled with the product name, model number, quantity, and handling instructions.
  • Documentation Enclosed: Confirm that installation manuals, technical files, and certificates are included in the shipment.

Handover Responsibilities

Clearly define handover responsibilities to avoid disputes and ensure a smooth installation. This is especially important if on-site assembly is involved.

  • Supplier Responsibilities: Provide installation drawings, torque specifications, and a sign-off checklist. If the supplier supervises assembly, they must ensure the final unit meets the standard.
  • Buyer Responsibilities: Ensure that the installation site is ready, and that local contractors follow the supplier’s instructions.
  • Transfer of Manufacturer Role: If the buyer or local contractor assembles the unit, they must formally accept manufacturer responsibilities. This should be documented in the contract.

Post-Installation Support

After installation, maintain a clear channel for post-market surveillance and support. The manufacturer (or the party assuming that role) must have a process for handling complaints and reporting serious incidents to regulators.

  • Complaint Handling: Ensure the supplier has a documented process for receiving and investigating complaints.
  • Vigilance Reporting: If the product is a medical device, the manufacturer must report serious incidents to the competent authority. Verify that this process is in place.
  • Spare Parts and Maintenance: Confirm the availability of spare parts and maintenance services for the expected lifespan of the unit.

Final Checklist for Overseas Buyers

Use this checklist to ensure you have covered all aspects of ISO/FDIS 11197:2026 compliance in your sourcing process:

  • RFQ includes questions on manufacturer status, documentation, testing, and EU MDR alignment.
  • Technical file index and sample pages reviewed.
  • Test reports verified from an accredited laboratory.
  • Quality system certificate (ISO 13485 or ISO 9001) checked.
  • EU MDR classification and DoC (if applicable) obtained.
  • On-site assembly responsibilities clearly defined in the contract.
  • Approval milestones set and documented.
  • Inspection plan agreed upon.
  • Packaging plan reviewed.
  • Handover responsibilities and post-installation support confirmed.

By following these practical steps, you can mitigate risks and ensure that your medical supply units meet the requirements of ISO/FDIS 11197:2026 and applicable regulations.

ZHOBAI Medical Furniture

Ready to Apply These Principles to Your Project?

Our engineering team responds to all project briefs within 24 hours. Share your FF&E scope — room count, property type, target timeline, and budget range — and we’ll provide a factory-direct assessment and indicative pricing within one business day.

Send Your Project Brief →